Size Chart
|
Flashers Size
|
1
|
2
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
Outside Pipe
Diameter (inch)
|
1/4"- 2"
|
1-3/4" - 3-1/4"
|
1/4" - 5"
|
3"- 6-1/4"
|
4-1/4" - 7-1/2"
|
5" - 9"
|
6" - 11"
|
7" - 13"
|
10" - 19"
|
Outside Pipe
Diameter (mm)
|
6-50mm
|
44-82mm
|
6-127mm
|
75-160mm
|
108-190mm
|
125-230mm
|
150-280mm
|
175-330mm
|
254-483mm
|
Base O.D.
Diameter
|
4-3/4"
|
6-1/4"
|
7-3/4"
|
9-1/4"
|
10-3/4"
|
12-1/4"
|
14-1/4"
|
16-1/2"
|
25-1/2"
|
Top Diameter
|
Closed
|
1-3/8"
|
Closed
|
2-1/4"
|
3-1/2"
|
4"
|
4-1/2"
|
5-1/2"
|
7-3/4"
|
Overall Height
|
3"
|
4"
|
4"
|
5"
|
5"
|
6"
|
6"
|
6"
|
8"
|
Carton Quantity
|
10
|
10
|
10
|
5
|
5
|
5
|
5
|
5
|
2
|
Square Pipe?
Flashers can be used on Square pipes also, to calculate which size is needed you multiply the dimensions of the four sides by 4 then divide the total figure by 3.142, see examples below:
Square pipe with 160mm faces, 160mm x 4 = 640mm divided by 3.142 = 203mm therefore a No. 6, 7 or 8 Flasher would be suitable but must be cut appropriately at the 200mm ring on the Flasher in this case.